Your browser doesn't support javascript.
loading
The approach on methods of replacing tracheostomy tube after incision of trachea in 48 hours / 中国医师进修杂志
Chinese Journal of Postgraduates of Medicine ; (36): 29-31, 2009.
Article in Chinese | WPRIM | ID: wpr-393695
ABSTRACT
Objective To explore the more secure and available methods in replacing traeheostomy tube.Methods Sixty patients with incision of trachea were divided into group A(29 eases)and group B (31 cases)randomly.The new method was used in group A with putting a catheter into the old tracheostomy tube before taking it out,and placing the new tracheostomy tube under the guide of catheter.While the traditional method was used in group B.The heart rate,SpO2,manipulation time,perioperative haemorrhage, and the condition of entering the false passage were recorded.Results The heart rate,SpO2 were no significant difference before and after manipulation in group A,but the heart rate increased and SpO2 decreased in group B(P<0.01 or<0.05).The manipulation time was(50.5±4.2) s in group A,and (84.9±5.3) s in group B(P<0.05).The perioperative haemorrhage >3 ml and the condition of entering the false passage in group A(2 Cases,o cage)were less than those in group B(15 cases.5 cases)(P<0.01 or<0.05).Conclusion The new method in replacing tracheostomy tube which use an input catheter is more security and more availability.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Postgraduates of Medicine Year: 2009 Type: Article