Your browser doesn't support javascript.
loading
Low-dose CT pulmonary angiography: a phantom study / 中华放射学杂志
Chinese Journal of Radiology ; (12): 753-758, 2009.
Article in Chinese | WPRIM | ID: wpr-394052
ABSTRACT
Objective To investigate the feasibility of reduced radiation dose for CT pulmonary angiography (CTPA) and the possible lowest radiation threshold by a phantom study.Methods The CT value difference between air within the trachea and the extracorporeal background region was measured in132 consecutive patients.A noise-measurement phantom and a pulmonary embolism (PE) phantom were made of phenol-formaldehyde, and both phantoms and a water phantom were scanned with standard and lower radiation doses as follow 280, 200, 160, 100, 90, 80, 70, 60, 50, 40, 30, 20, 15, and 10 mA respectively, at a fixed voltage of 120 kVp.Standard and soft tissue algorithms were used to reconstruct the images.Three experienced doctors independendy evaluate the image quality and the efficiency of detecting PE of the images with various doses.The Pearson correlation analysis, two-tailed paired t test, ANOVA, and Kappa test were employed for the statistical analysis.Results The CT value difference between air within the trachea and the extracorpereal background region in 132 consecutive patients ranged from 20.00 to 55.00 HU, which had a positive correlation with weight[(64.99±11.86) kg], weight-height ratio [(38.71±6.13) kg/m], and BMI[(23.11±3.38) kg/m2](r=0.228,0.374,0.449 respectively; P <0.01).The image noise level with soft-tissue reconstruction algorithm[(16.55±9.08), (16.42±9.40) HU]was significantly lower than that of the image with standard reconstruction algorithm[(22.43±11.25),(21.99±11.67) HU](F=4.316, P < 0.05).The image noise level with soft-tissue reconstruction algorithm at 100 mA was similar to that of the images with standard reconstruction algorithm at 280 mA, and the signal-w-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the image of PE phantom was 23.05 and 20.52 respectively, without any impairment in detectability of embolus.The image noise level with soft-tissue reconstruction algorithm at 60 mA was similar to that of the image with standard reconstruction algorithm at 160 mA, while the SNR and CNR was 18.01 and 15.97 respectively, also with acceptable detectability of embolus.When the tube current was reduced below 30 mA, the image quality decreased significantly, with the SNR and CNR was lower than 12.36 and 10.95 respectively, and the detectability of embolus was degraded.The consistency of the image quality grading by 3 observers was excellent(K=0.807,0.712,0.904 ,respectively; P < 0.01).Conclusions The 100 mA may potentially be the ideal low dose tube current setting, with radiation dose only equal to 36% of 280 mA (standard dose).The 30 mA may possibly be a minimum radiation dose for detecting PE.The soft-tiasue reconstruction algorithm was favorable in preserving the SNR when the radiation dose was reduced.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Radiology Year: 2009 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Radiology Year: 2009 Type: Article