Detection of myocardial coronary flow reserve of syndrome X by real-time myocardial contrast echocardiography / 中华超声影像学杂志
Chinese Journal of Ultrasonography
;
(12): 308-310, 2009.
Article
in Chinese
| WPRIM
| ID: wpr-395260
ABSTRACT
Objective To evaluate myocardial coronary flow reserve of syndrom X by real-time myocardial contrast echocardiography(MCE). Methods Ten patients with syndrome X and seven normal subjects were involved in the study. Real-time MCE was performed with acoustic contrast SonoVue,and the peak video density (A), and re-turgor velocity of microvessel (β), and the product of A ×β of quiescent condition and after adenosin loading were detected,and also the coronary flow reserve (CFR, the ratio of A xβ circa-adenosin loading). Results There was no significant difference of A between syndrom X and contrast group in quiescent condition, the β and product of A x β of patients with syndrome X were lower than those of contrast group, the CFR of syndrome X was obviously less than that of contrast group.Conclusions Myocardial microvessel function is abnormal in syndrome X, real-time MCE is useful for evaluate myocardial coronary flow reserve.
Full text:
Available
Index:
WPRIM (Western Pacific)
Type of study:
Diagnostic study
Language:
Chinese
Journal:
Chinese Journal of Ultrasonography
Year:
2009
Type: