Cerebral collateral magnetic resonance imaging / 中华神经科杂志
Chinese Journal of Neurology
;
(12): 179-182, 2009.
Article
in Chinese
| WPRIM
| ID: wpr-395995
ABSTRACT
Objective To evaluate collateral flows using vessel encoded arterial spin labeling (VE-ASL) perfusion imaging. MethodsVE-ASL was achieved to assess the presence and function of collateral flow on patients with internal carotid artery (ICA) stenosis. The presence of the anterior and posterior collateral flow was demonstrated by flow patterns of the A1 segment and posterior communicating artery (PCoA).Distal function of collateral flow of stenotic hemisphere was categorized as adequate ( cerebral blood flow ≥10 ml · min-1·100 g-1 ) or deficient (cerebral blood flow < 10 ml · min-1· 100 g-1 ). The results were compared with magnetic resonance angiography (MRA) and intraarterial digital subtraction angiography (DSA) in crosstable by using Kappa values. The VE-ASL before and after ICA stent therapy were compared. ResultsThe Kappa values of the flow patterns of AI segment and PCoA between VE-ASL and MRA were 0. 746 and 0. 700. The Kappa value of the function of collaterals using VE-ASL and DSA was914. VE-ASL showed collateral flow via leptomeningeal anastomoses. VE-ASL changed significantly after ICA steat therapy. ConclusionVE-ASL reveals the presence and distal function of collateral flow, which helps to evaluate the efficacy of ICA steat therapy.
Full text:
Available
Index:
WPRIM (Western Pacific)
Language:
Chinese
Journal:
Chinese Journal of Neurology
Year:
2009
Type:
Article
Similar
MEDLINE
...
LILACS
LIS