The multi-slice CT perfusion imaging in evaluating the prevention and treatment by edaravone on lung ischemia-reperfusion injury after pulmonary thromboembolism / 中华放射学杂志
Chinese Journal of Radiology ; (12): 1089-1094, 2008.
Article in Chinese | WPRIM | ID: wpr-398320
ABSTRACT
Objective To evaluate the multi-slice CT perfusion imaging in investigating whether edaravone can prevent and treat pulmonary thromboembolism ischemia-reperfusion injury(PTE-IRI).Methods Twenty mongrel canines were included.A Swan-Ganz catheter wag introduced into the right internal jugular vein using the Seldinger technique,and then was inserted into the pulmonary artery.Balloon occlusion of the right inferior lobe pulmonary artery for 4 h was followed by removing catheter and 4 h of reperfusion.Animals were divided into four groups of A(no edaravone during ischenmia and reperfusion),B(edaravone used only during ischemia),C(edaravone used during both ischemia and reperfusion)and D group(edaravone used only during reperfusion)(n=5 per group).Every group was divided into three time points including before ischemia,4 h after ischemia and 4 h after reperfusion.CT scan and CT perfusionwere performed at the three time points.The blood flow(BF),blood volume(BV)and mean transit time (MTT)of the bilateral inferior regional lung parenchyma were measured with the software of perfusion 3.Results CT examination showed pulmonary edema in the right inferior lung lobe at 4 h after reperfusion.(1)The BF and MTT of A,B,C and D group were[(259.4±15.7)ml·min-1·100 g-1,(293.7±7.9)ml·min-1·100 g-1,(379.4±14.5)ml·min-1·100 g-1,(382.5±16.6)ml·min-1·100 g-1]and[(3.1±0.2)s,(2.6±0.2)s,(2.2±0.1)s,(1.9±0.2)s]respectively at 4 h after reperfusion.The BF and MTT were statistically difierent(P<0.01)between groups(A and B,A and C,A and D,B and C,B and D)except between group C and D(the P value>0.05)at 4 h after reperfusion,but the BV was not statistically different between groups(P>0.05).(2)The BF[(397.2±19.2)ml·min-1·100 g-1and(259.4±15.7)ml·min-1·100 g-1in group A,(393.2±16.1)ml·min-1·100 g-1and(293.7±7.9)ml·min-1·100 g-1 in group B]and MTT[(1.8±0.1)8 and (3.1±0.2)s in group A,(1.8±0.2)s and(2.6±0.2)s in group B]were statistically different(P<0.01),but the BV[(12.0±0.9)ml/100 g and(12.2±1.0)ml/100 g in group A,(11.9±1.5)ml/100 g and(12.2±1.3)ml/100 g in group B]were not different(P>0.05)between groups before ischemia and 4 h after ischemia.The BF.MTT and BV were not statistically significant between before ischemia and4 h after reperfusion in group C and D(P>0.05).ConclusionsEdaravone can attenuate the degree of the PTE IRI.Multi-slice CT perfusion imaging can evaluate effect.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Radiology Year: 2008 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Radiology Year: 2008 Type: Article