Effects of three bond agents on bond strength of titanium- ceramic system / 实用口腔医学杂志
Journal of Practical Stomatology ; (6): 160-164, 2010.
Article in Chinese | WPRIM | ID: wpr-403341
ABSTRACT

Objective:

To evaluate the effects of three bond agents on bond strength of titanium- ceramic system.

Methods:

The pure titanium specimens were randomly divided into three groups. Three different manufacturers' porcelains(Super Ti22,Duceratin,Titankeramik) were used specially for titanium- ceramic bonding. The specimens in each group were further divided into two subgroupsbond agent group and no bond agent group. Bond strength of specimens was measured by the three- point bending test according to ISO9693. The titanium- ceramic interfaces were investigated by SEM/EDS.

Results:

The bond strength of Super Ti22(35.84±2.17) MPa and Duceratin(35.45±2.37) MPa with bond agent group was significantly higher than that of no bond agent group(P<0.05). Titankeramik with bond agent group showed a little higher bond strength than without bond agent, but no significant difference in statistics(P>0.05). The interfaces of Super Ti22 and Duceratin with bond agent groups were compact, while there were visible cracks and pores at the interface of other groups.

Conclusion:

The application of bond agent can improve bond strength of titanium- ceramic system.