Determination of methomyl in rat plasma by SPE-HPLC / 中国法医学杂志
Chinese Journal of Forensic Medicine ; (6): 386-388, 2009.
Article in Chinese | WPRIM | ID: wpr-405409
ABSTRACT
Objective To establish a method of solid phase extraction-reversed-phase high performance liquid chromatography(SPE-HPLC)for determination of methomyl in plasma of rat.Methods The sample pretreatment method,the test conditions,the linear range,the sensitivity,the specificity,the precision, the accuracy,the stability and the recoveries for plasma were investigated by using rat plasma spiked with standard methomyl and intemal standard substance.Results The linear range was 0.1~20μg/mL ( r= 0.9993,P<0.001).The limit of detection was 0.03μg/mL(S/N ≥3).The intra and inter-day precision of assay for methomyl was less than 8.33%and 11.11%in plasma respectively.The intra and inter-day accuracy of assay for methomyl was between 90%and 120%in plasma respectively.The recoveries for methomyl were more than 88%±4.4%in plasma.Conclusion The HPLC method for quantitative and qualitative analysis of methomyl is simple,rapid and accurate,which is suitable for the identification of methomyl in the cases.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Qualitative research Language: Chinese Journal: Chinese Journal of Forensic Medicine Year: 2009 Type: Article