Your browser doesn't support javascript.
loading
Vision-related theory-based design of vision detection system for dysopsia features in amblyopic patients New pathway for amblyopia screening / 中国组织工程研究
Chinese Journal of Tissue Engineering Research ; (53): 4211-4215, 2009.
Article in Chinese | WPRIM | ID: wpr-406548
ABSTRACT

BACKGROUND:

Previous studies have demonstrated that amblyopic patients have a variety of dysopsia compared with normal people.Engineered visual system could find amblyopia through detection of human visual system.

OBJECTIVE:

To screen sensitive indexes for amblyopia through visual function examination to establish a intemet-based amblyopia screening method.DESIGN,TIME AND

SETTING:

Randomized,blinded,and controlled experiment.The study was performed at Department of Optometry,People's Hospital of Guangxi Zhuang Autonomous Region from September to November 2008.

PARTICIPANTS:

A total of 80 volunteers undergoing visual examination in Department of Optometry,People's Hospital of Guangxi Zhuang Autonomous Region were selected,aged 4-19 years.All people had no organic diseases of eyes.They were divided into normal group (n=40) and ambiyopic group (n=40) according to their corrected visual acuity (whether > 4.9).

METHODS:

Using vision system,the various visual function indexes of each participant were examined.The data from single eye and both eyes were collected and analyzed using Fisher.The sensitive indexes were selected to establish identification function for amblyopia screening.MAIN OUTCOME

MEASURES:

Age,visual noise,orientation identification and contour integration of participants were examined.

RESULTS:

Results showed that age,visual noise,orientation identification and contour integration were clinically significant indexes,and cross validation suggested that the identification correct rate was 92.5%.The discriminant function of amblyopia was Y1=1.175X1+0.786X2+0.928X3+1.061X4-0.225X5+2.547X6+1.313X7-18.651;the discdminant function of normal vision was Y2=1.369X1+ 1.728X2+1.779X3+1.549X4-1.912X5+2.665X6+0.387X7 26.640.

CONCLUSION:

Visual noise,orientation identification and contour integration in vision detection system could be used to screen amblyopia in children,in particular with assistance of internat.
Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial / Diagnostic study / Screening study Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2009 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial / Diagnostic study / Screening study Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2009 Type: Article