Determination of evodiamine by high performance liquid chromatography-tandem mass spectrometry and pharmacokinetic studies in rats / 中国临床药理学与治疗学
Chinese Journal of Clinical Pharmacology and Therapeutics ; (12): 427-433, 2007.
Article in Chinese | WPRIM | ID: wpr-408033
ABSTRACT

AIM:

To establish an LC-MS/MS method for determination of evodiamine concentration in rat plasma and to study its pharmacokinetic profile in rats.

METHODS:

Six rats were administrated (i.g.) evodiamine at the dose of 100 mg/kg. Blood samples were collected from eye socket. Evodiamine concentration in rat plasma was determined by LC-MS/MS method. The pharmacokinetic parameters were calculated using DAS program.

RESULTS:

A good linear relationship was obtained in the concentration range (0.2-50.0 ng/mL) studied (r2=0.9997). Average recoveries ranged from 96.12% to 99.46%. Intra-and inter-day relative standard deviations were 4.61%-13.51% and 5.65%-11.49%, respectively. The main pharmacokinetic parameters of evodiamine were as follows Cmax (5.3±1.5) ng/mL; tmax (22±8) min; t1/2 (451±176) min.

CONCLUSION:

A selective and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the quantification of evodiamine in rat plasma is developed and validated. This method is successfully applied for the pharmacokinetic studies of evodiamine in rats.