Your browser doesn't support javascript.
loading
Pain-alleviating effect of bupivacaine polylactic acid microspheres in rabbits / 中国组织工程研究
Chinese Journal of Tissue Engineering Research ; (53): 181-183, 2006.
Article in Chinese | WPRIM | ID: wpr-408300
ABSTRACT

BACKGROUND:

Bupivacaine is widely used to alleviate post-operation pain and cure acute and chronic pain caused by inflammation or cancer.Its analgesic time cannot meet the request that drug is released slowly to prolong the analgesic time in clinic.

OBJECTIVE:

To detect the alleviating effect of bupivacaine polylactic acid microspheres taking high molecular polymer-polylactic acid as vector in rabbits with high performance liquid chromatograph (HPLC) and traditional skin test method.

DESIGN:

A completely randomized controlled animal experimental study.

SETTING:

School of Pharmacy, Second Military Medical University of Chinese PLAMATERIALS Sixteen New Zealand rabbits, weighing (2.58±0.17)kg were used in this experiment.

INTERVENTIONS:

The experiment was carried out at the Department of pharmaceutics, School of Pharmacy, Second Military Medical University of Chinese PLA between September and November 2002. ① Animal models were established according to traditional skin test method. ② Totally 16 New Zealand rabbits were randomly divided into 2 groups Group A and Group B, with 8 in each one. 5 mg/kg bupivacaine parenteral solution was injected subcutaneously in Group A, 5 mg/kg bupivacaine polylactic acid microspheres were implanted between subcutaneous tissue and sarcolemma in Group B. We took 1.5 mL blood from ear border vein at 5, 10, 20, 30,45 minutes, 1, 2, 3, 4, 6, 8, 12 and 24 hours after administration of bupivacaine parenteral solution respectively in Group A and another 1.5 mL at 0.5, 1, 2, 3, 4, 5, 6, 8, 12, 24, 3 6, 48 and 60 hours after admistration of bupivacaine microsphere powder for index detection. ③ HPLC method was used to detect the concentration and releasing effect of bupivacaine in blood serum.MAIN OUTCOME

MEASURES:

Concentration change of bupivacaine in blood serum and efficacy diameter of local anesthetic.

RESULTS:

All the 16 rabbits entered the stage of result analysis. ①Change of bupivacaine concentration Plasma bupivacaine concentration in Group A reached the peaked quickly after subutaneous injection with the high concentration of 2.466 4 mg/L, then declined quickly. Plasma bupivacaine concentration in Group B was relative stable, reached a peak much slowly after subcutaneous implantation, with peak concentration of 0.778 1 mg/L, and the plasma bupivacaine concentration maintained a relative low level, the mean retention time was obviously prolonged (P < 0.05).② Alleviating effect of bupivacaine The analgesic time was significantly longer in the bupivacaine microsphere group than in the bupivacaine parenteral solution group (P < 0.05).

CONCLUSION:

Bupivacaine polylactic acid microspheres have sustained release effects in rabbits.
Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2006 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2006 Type: Article