ABSTRACT
Objective To compare the analytical result of different kinds of film dose analysis software for the same gamma knife,analyze the reasons of difference caused,and explore the measurements and means for quality control and quality assurance during testing gamma knife and analyzing its result.Methods To test the Moon Deity gamma knife with Kodak EDR2 film and γ-Star gamma knife with GAFCHROMIC(R) EBT film,respectively.All the validation films are scanned to proper imagine format for dose analysis software by EPSON PERFECTION V750 PRO scanner.Then imagines of Moon Deity gamma knife are analyzed with Robot Knife Adjuvant 1.09 and Fas-09 1.0,and imagines of γ-Star gamma knife with Fas-09 and MATLAB 7.0.Results There is no significant difference in the maximum deviation of radiation field size ( Full Width at Half Maximum,FWHM) and its nominal value between Robot Knife Adjuvant and Fas-09 for Moon Deity gamma knife (t = -2.133,P >0.05).The analysis on the radiation field' s penumbra region width of collimators which have different sizes indicated that the differences are significant (t = - 8.154,P < 0.05 ).There is no significant difference in the maximum deviation of FWHM and its nominal value between Fas-09 and MATLAB for γ-Star gamma knife ( t = - 1.384,P >0.05 ).However,following national standards,analysis of φ4 mm width of collimators can obtain different results according to the two kinds software,and the result of Fas-09 is not qualified while MATLAB is qualified.The analysis on the radiation field' s penumbra region width of collimators which have different sizes indicates that the differences are significant ( t = 3.074,P < 0.05 ).The imagines are processed with Fas-09.The analysis of imagine in the pre-and the post-processing indicates that there is no significant difference in the maximum deviation of FWHM and its nominal value ( t = 0.647,P > 0.05 ),and the analytical result of the radiation field' s penumbra region width indicates that there is no significant difference as well ( t = -0.627,P > 0.05 ).Conclusion The study shows that different kinds of film dose analysis software may have some differences in analysis of the same gamma knife validation film,and the results may lead to the different decisions in accordance with national standard.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Radiological Medicine and Protection Year: 2011 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Radiological Medicine and Protection Year: 2011 Type: Article