Research on perfusion weighted imaging and diffusion weighted imaging of pancreatic masses at 3.0 T MR / 中华放射学杂志
Chinese Journal of Radiology ; (12): 646-652, 2011.
Article in Chinese | WPRIM | ID: wpr-416561
ABSTRACT
Objective To investigate the value of MR perfusion parameters and ADC in the diagnosis of pancreatic cancer and pancreatic mass at 3.0 T MR. Methods Twenty healthy volunteers and 25 patients with pancreatic cancers proven by pathological results underwent MR PWI at a 3.0 T scanner. A two-compartment model was used to quantify Ktrans, Kep and Ve in the pancreatic cancer, adjacent pancreatic tissue, distal inflammatory pancreatic tissue and normal pancreatic tissue. All parameters among different tissues were analyzed and compared with ANONA. Fifteen normal volunteers and 58 patients, including 30 patients with pancreatic cancer (proven histopathologically), 9 patients with pancreatitis pseudotumor (4 patients proven by histopathological results, 5 patients proven by follow-up after treatment), 9 patients with solid pseudopapillary tumor of pancreas (SPTP, proven histopathologically) and 10 patients with pancreatic neuroendocrine tumor (PET, proven by histopathology), underwent respiratory-triggered DWI on 3.0 T. ADC values of normal pancreas and all types of pancreatic lesions were statistically analyzed and compared with ANONA. ROC curve was used to analyze the diagnostic power of ADC value. Results Ktrans of pancreatic cancer, adjacent pancreatic tissue, distal inflammatory pancreatic tissue and normal pancreatic tissue were (1.66±1.25), (3.77±2.67),(1.16±0.94) and (2.69±1.46)/min respectively(F=8.160, P<0.01). LSD test showed that Ktrans in the pancreatic cancer was statistically lower than that in normal pancreas (P=0.011)and adjacent pancreatic tissue(P=0.002). Kep of pancreatic cancer, adjacent pancreatic tissue, distal inflammatory pancreatic tissue and normal pancreatic tissue were (2.53±1.55), (5.64±2.64), (1.70±0.91) and (4.28±1.64)/min respectively(F=4.544, P<0.01). LSD test revealed that Kep in pancreatic cancer was statistically lower than that in normal pancreatic tissue (P=0.035)and adjacent pancreatic tissue(P=0.041). The median of Ve among the pancreatic cancer, adjacent pancreatic tissue, distal inflammatory pancreatic tissue and normal pancreatic tissue were 0.926, 0.839, 0.798 and 0.659 respectively (χ2=12.040,P<0.01). Ve in pancreatic cancer was statistically higher than that in normal pancreatic tissue (P=0.002). ADC values of the pancreatic cancer, pancreatitis pseudotumor, SPTP, PET and normal pancreas were(1.57±0.26)×10-3,(1.19±0.15)×10-3,(1.05±0.35)×10-3,(1.62±0.41)×10-3 and (1.82±0.25)×10-3 mm2/s(F=21.681, P<0.01). LSD test showed there were significant statistical differences in ADC values among pancreatic cancer, pancreatitis pseudotumor and normal pancreatic tissue (P<0.01). ROC curve disclosed that the sensitivity, specificity, positive predictive value and negative predictive value were 86.7%, 88.9%, 96.3% and 66.7% respectively, when ADC≥1.33×10-3 mm2/s was used as a cutoff value for differential diagnosis of PDCA from MLP. The sensitivity, specificity, positive predictive value and negative predictive value were 77.8%, 100.0%, 100.0% and 83.3% respectively when ADC≤1.25×10-3 mm2/s was used as a cutoff value for differential diagnosis of SPTP from PET. Conclusion Compared to normal pancreatic tissue, pancreatic cancer usually had a lower Ktrans, Kep and larger Ve. ADC values from respiratory-triggered DWI were well related to histopathological features of pancreatic entities and may be helpful in the differential diagnosis.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Chinese Journal of Radiology Year: 2011 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Chinese Journal of Radiology Year: 2011 Type: Article