Your browser doesn't support javascript.
loading
"Leukocyte differential count in peripheral blood ""with"" single tube/ten colors""flow cytometry" / 中华检验医学杂志
Chinese Journal of Laboratory Medicine ; (12): 395-402, 2011.
Article in Chinese | WPRIM | ID: wpr-417238
ABSTRACT
Objective To explore the values of potential clinical application ofsingle tube/ten colorsflow cytometry for leukocyte differential count in peripheral blood.Methods Utilizing multiple monoclonal antibody combinations and the vavious logical gating strategies,the single tube/12 antibodies with no-wash method for the leukocyte differential count in peripheral blood were determined by using 10 colors flow cytometry.Leukocyte differentials of 142 peripheral blood samples were determined by both Beckman-Coulter LH750 hematology analyzer and 10 colors flow cytometry.The results were then compared to standard microscopic examination as a reference method.The clinical diagnostic efficiency ofsingle tube/10 colorsflow cytometry was calculated.The correlations between standard microscopic cytology,single tube/10 colorsflow cytometry and the hematology analyzer were determined.In addition,the clinical diagnosis efficiency for blast counts ofsingle tube/10 colorswere compared to the results determined by BD FACS Calibur flow cytometer.Results The leukocyte differentials were correlated well between the single tube/10 colorsflow cytometry and standard microscopic cytology(r>0.700,P<0.01) except for basophils.The correlations with neutrophilic granulocytes,lymphocytes,immature granulocytes and blasts were superior(r=0.972,0.951,0.801,0.912,respectively,P<0.01).When 1% was selected as the cut-off point for immature granulocytes determined by standard microscopic cytology,the sensitivity and the specificity ofsingle tube/10 colorsflow cytometry were 92%(57/62) and 79% (63/80),respectively.When 0.5% was selected as the cut-off point for blasts detected by standard microscopic cytology,the sensitivity and the specificity were 99% (67/68) and 92% (68/74).Using the immunophenotyping results from BD FACS Calibur as a standard,the sensitivity for detecting blasts bysingle tube/10 colOrsflow cytometry was 100% (40/40),the specificity was 91% (10/11),the positive predictive value was 98% (40/41),the negative predictive value was 100% (10/10) and the accuracy was 98% (50/51).Conclusions Thesingle tube/10 colorsflow cytometry has a excellent correlation with the standard microscopic cytology when applied on leukocyte differential count in peripheral blood.It may potentially use as a subsequent method for verification of abnormal results of complete blood cell count in the future.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Laboratory Medicine Year: 2011 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Laboratory Medicine Year: 2011 Type: Article