Analysis on sensitivity of contrast-enhanced ultrasound and ultrasonic elastography in detecting different sizes of thyroid papillary carcinoma / 中华超声影像学杂志
Chinese Journal of Ultrasonography
;
(12): 321-324, 2013.
Article
in Chinese
| WPRIM
| ID: wpr-434782
ABSTRACT
Objective To explore the sensitivity of contrast-enhanced ultrasound (CEUS) and ultrasonic elastography(UE) in detecting different sizes of thyroid papillary carcinoma.Methods 64 cases of thyroid papillary carcinoma were divided into two groups according to the diameter size(group 1,≤1 cm;group 2,> 1 cm) and examined by the contrast-enhanced ultrasound and elastography,then the features were analyzed and the sensitivity for detecting of the two methods in different groups were compared.Results The sensitivity for detecting in CEUS was higher than in UE,which had significant difference between two methods.CEUS and UE were valuable for detecting and they had no difference in sensitivity for detecting in group 1.There was a significant difference in sensitivity for detecting between two methods in group 2.Conclusions Both CEUS and UE were valuable in diagnosis of thyroid papillary carcinoma and the sensitivity for detecting in CEUS is higher than in UE in group 2.
Full text:
Available
Index:
WPRIM (Western Pacific)
Type of study:
Diagnostic study
Language:
Chinese
Journal:
Chinese Journal of Ultrasonography
Year:
2013
Type:
Article
Similar
MEDLINE
...
LILACS
LIS