Study on the method of decoloration for immunohistochemical HE slides / 中国基层医药
Chinese Journal of Primary Medicine and Pharmacy
; (12): 3420-3422, 2013.
Article
in Zh
| WPRIM
| ID: wpr-436794
Responsible library:
WPRO
ABSTRACT
Objective To explore the different methods of decoloration for immunohistochemical HE slides,and their influence on tissue antigen expression.Methods Antigen retrieval solution (EDTA or citric acid solution) was used in immunohistochemistry to decolor HE slides,and was compared with the method of hydrochloric acid solution decoloration in normal temperature.Results Antigen heat retrieval decolors completely.Compared with other methods,it has shorter decoloration time (1 ~ 2min),more than 90% of completely decoloration rate,the difference was significant(x2 =27.6,23.9,all P < 0.01).Meanwhile,the method dose not damage slides,and the immunohistoehemical results are exact,without background coloring and unusual coloring,antigen expression rate and intensity are high.Conclusion Antigen heat retrieval decoloration not only simplifies the coloration process,but also protects tissue antigen activity better.It is the preferable method of decoloration and protecting antigen resource,which possesses some practical value in the pathology diagnosis.
Full text:
1
Index:
WPRIM
Language:
Zh
Journal:
Chinese Journal of Primary Medicine and Pharmacy
Year:
2013
Type: