ABSTRACT

BACKGROUND:

Polyurethane has good mechanical and physical characteristics and is extensively used in clinical and experimental studies, but its hydrophobicity and histocompatibility are not ideal, which limits its use in tissue engineering as a biomaterial scaffold to some extents.

OBJECTIVE:

To observe the hydrophilicity of polyurethane membrane grafted with silk fibroin and glutin and its compatibility with human hypopharyngeal cel s.

METHODS:

The changes in hydrophilicity of polyurethane membrane grafted with silk fibroin and glutin were detected by contact angle measurements. Human hypopharyngeal fibroblasts were cultured in vitro on polyurethane membrane, silk fibroin-polyurethane membrane, glutin-polyurethane membrane and tissue culture plate. Cel compatibility was compared using cytometry and cel morphology obsevation. RESULTS AND

CONCLUSION:

Hydrophilicity of silk fibroin-or glutin-polyurethane membranes significantly increased (Pglutin-polyurethane membrane (Pthan that on the polyurethane membrane, especial y on the silk fibroin-polyurethane membrane. These suggested that hydrophilicity and cel compatibility of silk fibroin-or glutin-polyurethane membrane were elevated.