Your browser doesn't support javascript.
loading
Comparison efficiency of three-dimensional speckle tracking and two-dimensional speckle tracking imaging in detecting significant coronary artery stenosis / 中华超声影像学杂志
Chinese Journal of Ultrasonography ; (12): 654-658, 2013.
Article in Chinese | WPRIM | ID: wpr-442619
ABSTRACT
Objective To analyzed the left ventricular (LV) regional and global strains in coronary artery stenosis by using three-dimensional speckle tracking imaging (3D-STI) and two-dimensional speckle tracking imaging (2D-STI) for the assessment of left ventricular systolic function,and to compare the clinical values between 3D-STI and 2D-STI in the detection of coronary stenosis.Methods 39 patients with coronary artery stenosis and 32 sex-age matched controls were enrolled in this study.Coronary artery stenosis group was divided into ischemic group and non-ischemic group.Real-time three dimensional full volume and two-dimensional dynamic image of the LV were obtained and then analyzed by off-line analysis software.The parameters of 3D-STI were three-dimensional longitudinal strain (3D-LS),circumferential strain (3D-CS),radial strain (3D-RS),area strain (3D-AS),global longitudinal strain (3D-GLS),global circumferential train (3D-GCS),global radial strain (3D-GRS) and global area strain (3D-GAS).The parameters of 2D-STI were two-dimensional longitudinal strain (2D-LS),circumferential strain (2D-CS),radial strain (2D-RS),global longitudinal strain (2D-GLS),global circumferential train (2D-GCS) and global radial strain (2D-GRS).The global/regional strains derived from 3D-STI and 2D-STI in patient group and controls were analyzed for comparing their efficacy in detecting coronary artery stenosis.Results Compared with non-ischemic group,2D-LS,2D-CS,3D-LS,3D-CS and 3D-AS were lower in ischemic group (P <0.05).ROC curves showed the sensitivity of 2D-LS,3D-LS and 3D-AS for the diagnosis of myocardial ischemia was 60.1%,64.2 % and 74.0 %,while the specificity of them was 60.0%,61.0% and 63.1%,respectively.There was no significant difference in 2D-GCS and 2D-GRS between coronary artery stenosis group and control group (P > 0.05).Compared with control group,2D-GLS,3D-GLS,3D-GCS,3D-GRS and 3D-GAS were significantly lower in coronary artery stenosis group (P <0.05).ROC curves showed the sensitivity of 2D-GLS,3D-GLS and 3D-GAS in the diagnosis of coronary artery stenosis was 61.3%,73.3% and 79.3 %,while the specificity was 65.4%,66.0 % and 70.8 %,respectively.The sensitivity and specificity of 3D-GAS were the highest in these parameters.It is revealed that 2D-GLS,2D-GCS and 2D-GRS were correlated with LVEF (r1 =-0.668,P1 <0.001 ;r2 =-0.551,P2 <0.001 ;r3 =0.310,P3 <0.05),and 3D-GLS,3D-GCS,3D-GRS,3D-GAS were correlated with LVEF (r1 =-0.634,P1 <0.001 ;r2 =-0.672,P2<0.001 ;r3 =0.698,P3<0.001 ;r4 =-0.707,P4<0.001).The correlate of 3D-GAS and LVEF was higher than other parameters.Conclusions 3D-STI is superior to 2D-STI in assessing regional and global left ventricular systolic function in patients with coronary artery stenosis,and 3D-GAS derived from 3D-STI is a ideal parameter of detecting significant coronary artery stenosis based on its highest sensitivity and specificity.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Ultrasonography Year: 2013 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Ultrasonography Year: 2013 Type: Article