Your browser doesn't support javascript.
loading
Evaluate the security of the treatment of a new bioartificial liver system with experimental pig model / 重庆医学
Chongqing Medicine ; (36): 1038-1040, 2014.
Article in Chinese | WPRIM | ID: wpr-444972
ABSTRACT
Objective To evaluate the security of big animals with a new bioartificial liver system .Methods Six Tibet pigs re-spectively received treatment of hybrid artificial liver and simple bioartificial liver ,observed and recorded the vital signs ,venous pressure ,transmembrane pressure and slurry pot pressure each hour ,and collected blood to make endotoxin and bacterial culture test in the zero hour ,fourth and eighth hour .Results Compared with the zero hour ,venous pressure ,transmembrane pressure ,slur-ry pot pressure were much higher in the fifth hour (P0 .05) .The mean arterial pressure and respiratory rate in all time point showed no significant changes (P>0 .05) .Com-pared with the zero hour ,the heart rate was much lower in the second hour (P<0 .01) .The values of blood endotoxin were less than 0 .5 EU/mL in the zero hour ,fourth and eighth hour from beginning ,and the bacterial culture test showed no growth of bacteria . Conclusion The experiment of big animals with a new bioartificial liver system was safe ,the efficacy in the treatment of hepatic failure could be assessed further .

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chongqing Medicine Year: 2014 Type: Article