Your browser doesn't support javascript.
loading
Causes of the complications in the patients with femoral peritrochanteric fractures with gamma3 nail / 中华骨科杂志
Chinese Journal of Orthopaedics ; (12): 736-742, 2014.
Article in Chinese | WPRIM | ID: wpr-450816
ABSTRACT
Objective To evaluate the causes of complications of patients with femoral Intertrochanteric fractures after gamma3 nail fixation.Methods A retrospective analysis was conducted to summarize the treatment of intertrochanteric fractures in 186 cases with Gamma3 nail from May 2006 to July 2011.Complications occurred in 24 cases during the operations.19 were males,5 females,with the age from 42 to 81,the average age of 69.00±3.27 years.According to AO/OTA classification,8 cases were type A1,1 case were type A2.1,15 cases were type A3.All patients included were acute fractures,while pathological fractures were excluded.Supine position were selected during operation,close reduction were performed in traction bed.Gamma3 nail made by Stryker Company was used to fix fractures through small incisions.Operational times were from 45 to 160 minutes,averaged by 80 min.Blood lose were 300-800 ml in average.No patient need blood transfusion.The procedure from hospitalized to operation is from 3 to 12 days,6 days in average,discharged from 3 to 16 days after operation.According to the intraoperative and postoperative follow-up evaluation of the X-ray and Harris evaluation criteria,Gamma3 nail complications were summarized in the application.Results Time of surgery in 24 cases were 45-160 min,average 80 min.Blood loss were 300-800 ml,average 600 ml,walking time 35-106 d.Harris evaluation were 75-91 point,average 81 point.The anti-spiral nail dropped into inner thigh muscles occurred in 1 case,causing defects of femoral lateral wall in 3 cases.Splitting fractures occurred in the proximal femoral shaft during the operations in 5 cases,poor fracture reduction during closed reduction in 6 cases.Fracture site were shifted lately postoperative in 5 cases,lag screw cut-out in 3cases and refracture in the site of distal femoral interlocking nail in 1 case.Conclusion Higher incidence of complications were occurred in some special types of AO classification when using close reduction and short Gamma3 nail.The reduction method,wrong indication selection and unreasonable application of equipment may result in the occurence of complications.We,therefore,should use long or short Gamma nail according to their respective induction method and scope of its application,aiming to avoid complications.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Etiology study Language: Chinese Journal: Chinese Journal of Orthopaedics Year: 2014 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Etiology study Language: Chinese Journal: Chinese Journal of Orthopaedics Year: 2014 Type: Article