The effects of commonly used dental cast metal posts and cores on MRI / 实用口腔医学杂志
Journal of Practical Stomatology
; (6): 460-463, 2014.
Article
in Zh
| WPRIM
| ID: wpr-454193
Responsible library:
WPRO
ABSTRACT
Objective:To observe the influence of commonly used dental cast metal posts and cores on magnetic resonance imaging (MRI)for head and neck.Methods:Six kinds of posts and cores made of metal alloy (Ni-Cr alloy,Co-Cr alloy,titanium alloy,pure titanium,Pd-Au alloy and Au-Pt alloy)were respectively fixed on the mucosa of left palate of a volunteer.The maxillofacial region of the subjects was scanned by routine head sequences SE-T1WI and TSE-T2WI respectively.Results:ANOVA of factorial design analy-sis indicated significant differences of artifacts among metal materials(F=153.63,PCo-Cr alloy>Ni-Cr alloy>Au-Pt alloy>titanium alloy>pure titanium;two posts and cores>one post and core;SE-T1WI>TSE-T2WI.Conclusion:Different cast metal posts and cores have different influences on MRI artifact.Reasonably choosing the metal materials and scanning sequences can minimize artifacts on MRI.
Full text:
1
Index:
WPRIM
Language:
Zh
Journal:
Journal of Practical Stomatology
Year:
2014
Type:
Article