Your browser doesn't support javascript.
loading
Measurement of physiological parameters in Bama minipigs by telemetry technology / 中国比较医学杂志
Article in Zh | WPRIM | ID: wpr-456083
Responsible library: WPRO
ABSTRACT
Objective To measure the circadian rhythm of consecutive monitoring electrocardiogram ( ECG ) , blood pressure, respiration, activities in Bama minipigs by telemetry technology .Methods Six 6-month-old Bama minipigs were implanted with VAP port in Superficial femoral artery , after recovery 7 days , 24 hours ECG , blood pressure, activity and respiratory parameters were recorded and analyzed in the EMAK noninvasive telemetry system . Results The ECG, blood pressure, respiration and activities in Bama minipigs showed circadian rhythm changes , Bama minipigs daytime heart rate was significantly higher than the nighttime heart rate (P <0.01), and daytime PR interval , QRS interval and QT interval was significantly lower than the nighttime (P <0.05, P <0.01), daytime mean heart rate was 76.22 beats/min, nighttime mean heart rate was 67.03 night beats/min;daytime mean PR interval , QRS interval andQT interval were 109.97 ms, 42.72 ms and 380.37 ms, nighttime mean PR interval , QRS interval and QT interval were 112.32ms, 44.01ms and 389.24ms.Bama minipigs daytime systolic blood pressure , diastolic blood pressure and mean blood pressure were significantly higher than the nighttime ( P <0.01 ) , daytime mean systolic blood pressure , diastolic blood pressure and mean blood pressure were 129.57 mmHg, 96.75 mmHg and 111.73 mmHg, nighttime mean systolic blood pressure , diastolic blood pressure , mean blood pressure were 122.81 mmHg, 92.65 mmHg and 106.19 mmHg, and the nighttime reduction rate of systolic blood pressure , diastolic blood pressure and mean blood pressure were 19.89%, 19.05%and 19.35%.In addition , Bama minipigs daytime activity and respiratory rate were significantly higher than the nighttime (P <0.01).Conclusion It’s Feasible to measure the circadian rhythm of electrocardiogram (ECG), blood pressure, activity and respiratory parameters in Bama minipigs by telemetry technology , and can truly shows those physiological parameters of the Bama minipigs within 24h, to provide a reference for pharmacology and toxicology research by using Bama minipigs .
Key words
Full text: 1 Index: WPRIM Language: Zh Journal: Chinese Journal of Comparative Medicine Year: 2014 Type: Article
Full text: 1 Index: WPRIM Language: Zh Journal: Chinese Journal of Comparative Medicine Year: 2014 Type: Article