Your browser doesn't support javascript.
loading
Research on CT diagnosis of hypoxic ischemic encephalopathy in neonates / 中国医学装备
China Medical Equipment ; (12): 115-117, 2014.
Article in Chinese | WPRIM | ID: wpr-456590
ABSTRACT

Objective:

Imaging features of hypoxic ischemic encephalopathy in neonates on CT scan were analyzed.

Methods:

Eight six cases of hypoxic ischemic encephalopathy in neonates were collected, and the pathogenesis, CT image characteristics were analyzed.

Results:

All of 86 cases have brain edema in different degree, and complicated with subarachnoid hemorrhage in 29 cases, subarachnoid and subdural hemorrhage in three cases, intracranial hemorrhage breaking into ventricles in one case and subdural hemorrhage with subcutaneous bleeding in one case.

Conclusion:

CT scan is valuable for detect the hypoxic ischemic encephalopathy in neonates and its follow-up examination.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study Language: Chinese Journal: China Medical Equipment Year: 2014 Type: Article