Your browser doesn't support javascript.
loading
Comparative study of real-time two-dimensional shear wave elastography and real-time tissue elastography in the assessment of liver fibrosis in chronic liver disease / 中华超声影像学杂志
Chinese Journal of Ultrasonography ; (12): 944-947, 2014.
Article in Chinese | WPRIM | ID: wpr-458010
ABSTRACT
Objective To compare the value of two‐dimensional shear wave elastography (2D‐SWE) and real‐time tissue elastography (RTE) in the assessment of liver fibrosis in patients with chronic liver disease. Methods One hundred and ten patients with chronic liver disease scheduled for liver biopsy were studied. Both 2D‐SWE and RTE were performed on these patients in a same day. The correlation coefficient of liver fibrosis level, receiver operating characteristic (ROC) curve of S≥2, and S=4 of 2D‐SWE and RTE were compared according to pathologic results. Results The correlation coefficient of liver fibrosis level for 2D‐SWE ( r =0 7.76, 95% CI 0 6.83 -0 8.45, P =0.000) was higher than that of RTE ( r =0 5.61, 95% CI 0 4.07-0 6.84, P =0.000)( Z =2 9.3, P =0.003). The area under ROC curve for S≥2 and S=4 of 2D‐SWE were 0 8.66 and 0 9.57 respectively, RTE were 0 7.50 and 0 8.43 respectively, which indicated that 2D‐SWE was better than RTE. Conclusions The diagnostic performance of 2D‐SWE was better than RTE for the assessment of liver fibrosis and cirrhosis.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Chinese Journal of Ultrasonography Year: 2014 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Prognostic study Language: Chinese Journal: Chinese Journal of Ultrasonography Year: 2014 Type: Article