Comparison of High Volume Zero-Balanced Ultrafiltration With Different Replacement Fluid in Infant Patients / 中国循环杂志
Chinese Circulation Journal
;
(12): 917-920, 2014.
Article
in Chinese
| WPRIM
| ID: wpr-458743
ABSTRACT
Objective:
To compare the clinical effects of high volume zero-balanced ultraifltration (ZBUF) with different replacement lfuid in infant patients.Methods:
A total of 40 infant patients who received aortic coarctation with deep hypothermic circulatory arrest operation in our hospital from 2012-11 to 2014-02 were summarized. The patients were randomized into 2 groups, Group A, the patients had ZBUF with plasmalyte A, n=21 and Group B, the patients had ZBUF with modiifed replacement lfuid n=19. All patients received ZBUF (15-20) ml/kg during re-warming period until the temperature reached 34°C at rectum. Blood gas analysis were conducted at 4 time points as T1 (before CPB), T2 (open ascending aorta and 5 min after calcium perfusion), T3 (ifnishing ZBUF) and T4 (end of CPB). The intra-operative CPB time and the post-operative recovery with the complication were recorded in all patients.Results:
For blood gas analysis, the calcium concentration was higher in Group B than that in Group A at T3 time point, P0.05. The other indexes were similar between 2 groups, P>0.05 and the post-operative recovery was similar between 2 groups, P>0.05.Conclusion:
ZBUF with modiifed replacement lfuid could avoid decreased calcium concentration and acidosis, therefore, provide a relative stable homeostasis in infant patients.
Full text:
Available
Index:
WPRIM (Western Pacific)
Type of study:
Controlled clinical trial
Language:
Chinese
Journal:
Chinese Circulation Journal
Year:
2014
Type:
Article
Similar
MEDLINE
...
LILACS
LIS