Your browser doesn't support javascript.
loading
Comparison of High Volume Zero-Balanced Ultrafiltration With Different Replacement Fluid in Infant Patients / 中国循环杂志
Chinese Circulation Journal ; (12): 917-920, 2014.
Article in Chinese | WPRIM | ID: wpr-458743
ABSTRACT

Objective:

To compare the clinical effects of high volume zero-balanced ultraifltration (ZBUF) with different replacement lfuid in infant patients.

Methods:

A total of 40 infant patients who received aortic coarctation with deep hypothermic circulatory arrest operation in our hospital from 2012-11 to 2014-02 were summarized. The patients were randomized into 2 groups, Group A, the patients had ZBUF with plasmalyte A, n=21 and Group B, the patients had ZBUF with modiifed replacement lfuid n=19. All patients received ZBUF (15-20) ml/kg during re-warming period until the temperature reached 34°C at rectum. Blood gas analysis were conducted at 4 time points as T1 (before CPB), T2 (open ascending aorta and 5 min after calcium perfusion), T3 (ifnishing ZBUF) and T4 (end of CPB). The intra-operative CPB time and the post-operative recovery with the complication were recorded in all patients.

Results:

For blood gas analysis, the calcium concentration was higher in Group B than that in Group A at T3 time point, P0.05. The other indexes were similar between 2 groups, P>0.05 and the post-operative recovery was similar between 2 groups, P>0.05.

Conclusion:

ZBUF with modiifed replacement lfuid could avoid decreased calcium concentration and acidosis, therefore, provide a relative stable homeostasis in infant patients.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial Language: Chinese Journal: Chinese Circulation Journal Year: 2014 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Controlled clinical trial Language: Chinese Journal: Chinese Circulation Journal Year: 2014 Type: Article