Your browser doesn't support javascript.
loading
A Case of Perigraft Seroma in Chronic Hemodialysis Patient / 대한신장학회잡지
Korean Journal of Nephrology ; : 510-512, 1999.
Article in Korean | WPRIM | ID: wpr-46093
ABSTRACT
Perigraft seroma is uncommon complication of polytetrafluoroethylene(PTFE) grafts applied as an arteriovenous shunt for hemodialysis. It is a collection of clear, sterile fluid confined to nonsecretory fibrous pseudomembrane, most commonly localized around the middle and distal portion of graft. The possible etiologic factors of perigraft seroma include poor graft incorporation, mechanical graft damage caused by alcohol and povidone-iodine, intraoperative streching of the graft, variations in quality control at the time of manufacture and contributing factors such as anemia and coagulopathy in uremia. The best strategy for management of perigraft seroma is not clear. spiration or drainage alone is not effective, and some authors advocate graft removal. We report a case of perigraft seroma around arterial end of PTFE graft along with a brief review of the literatures.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Polytetrafluoroethylene / Povidone-Iodine / Quality Control / Uremia / Drainage / Renal Dialysis / Transplants / Seroma / Anemia Limits: Humans Language: Korean Journal: Korean Journal of Nephrology Year: 1999 Type: Article