Your browser doesn't support javascript.
loading
Stainless steel locking plate implantation for fractures of the proximal humerus:restoration of joint function and incidence of adverse events / 中国组织工程研究
Chinese Journal of Tissue Engineering Research ; (53): 1812-1816, 2015.
Article in Chinese | WPRIM | ID: wpr-465646
ABSTRACT

BACKGROUND:

During ordinary plate fixation, the soft tissues around the fracture of the proximal humerus are nearly stripped to impact blood supply, and moreover, an ordinary steel plate cannot meet with the fixed requirements for severe osteoporosis, large bone defects and comminuted fractures.

OBJECTIVE:

To observe the functional recovery and complications in middle-aged patients with proximal humeral fractures undergoing stainless steel locking plate implantation.

METHODS:

From March 2011 to March 2014, 48 patients with proximal humeral fractures were treated in the 306th RESULTS AND

CONCLUSION:

The 48 patients were folowed up for 6-17 years, and the mean healing time was (15.3±1.2) weeks. At the last folow-up, the Neer scores were excelent in 12 cases, good in 22 cases, fair in 11 cases and poor in 3 cases, with an excelent-good rate of 71%. After internal fixation, there was one case of Hospital of PLA, including 20 males and 28 females, with an average age of 58 years. Of the 48 cases, there were 9 cases of Neer 2 fractures, 26 cases of Neer 3 fractures, and 13 cases of Neer 4 cases, al of which belonged to closed injuries. Al the patients were subject to locking plate implantation for repair of fractures of the proximal humerus, and evaluated based on Neer scores. soft tissue infection, two cases of traumatic arthritis, and no bone ununion and osteomyelitis. These findings suggest that the stainless steel locking plate implantation for repair of fractures of the proximal humerus can achieve a good anatomic reduction under minimaly invasive conditions and produce a stable rehabilitation environment for the soft tissue around the shoulder joint by internal fixation. Hence, the factures can recover faster with less complications. The stainless steel locking plate implantation can obtain good achievements in the repair of proximal humeral fractures of Neer 2, 3 as wel as Neer 4 in young patients with good bone quality.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Incidence study Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Incidence study Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2015 Type: Article