Your browser doesn't support javascript.
loading
Parameters of quantitative multi-slice CT imaging technology in pulmonary / 中国医学影像技术
Chinese Journal of Medical Imaging Technology ; (12): 351-354, 2010.
Article in Chinese | WPRIM | ID: wpr-471249
ABSTRACT
Objective To evaluate the relevance of MSCT pulmonary function parameters and pulmonary function test (PFT) parameters, and to define the reference value of MSCT pulmonary function parameters. Methods Thirty male volunteers received clinical PFT and MSCT scan. MSCT scan was perfomed at the end of the maximum inspiratory and maximum expiratory. All data were analyzed with the lung analysis software of computer-aided inspection system correlatedly with pulmonary function parameters. Results The lung volume at full inspiratory volume (Vin) and full expiratory volume (Vex) in MSCT scan had good correlation with total lung capacity (TLC) and residual volume (RV) (r=0.90, P<0.01; r=0.74, P<0.01). Vex/Vin was correlated with RV/TLC (r=0.74, P<0.01), and Vin-Vex was correlated with MVC (r=0.85, P<0.01). In inspiration, the average lung density was (-879.51±32.82) HU, the density per unit volume was (0.12±0.03) g/cm3, while in expiratory they were (-688.14±62.38) HU and (0.31±0.06) g/cm3. Conclusion MSCT pulmonary function tests with the analysis software of computer-aided inspection system have good correlation with PFT.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Medical Imaging Technology Year: 2010 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Medical Imaging Technology Year: 2010 Type: Article