Optimal dose research on manganese-enhanced MRI of rats optic nerve tracking / 实用放射学杂志
Journal of Practical Radiology ; (12): 1370-1373, 2015.
Article in Chinese | WPRIM | ID: wpr-477075
ABSTRACT
Objective To investigate the optimal concentration of manganese-enhanced MRI (MEMRI)in the visual pathway of experimental rats.Methods Sprague-Dawley rats were intravitreally injected with 3 μL of 10 - 100 mmol/L MnCl2 ,respectively. The contrast-to-noise ratio (CNR)of MEMRI for optic nerve(ON)and midbrain superior colliculus (SC)enhancement were measured at differ-ent concentrations of MnCl2 .Results The ON and SC were all clearly detected by MEMRI 24 h after unilateral intravitreal injected 10-100 mmol/L MnCl2 ,respectively.The CNR increased with the increasing concentration of MnCl2 from 10 to 50 mmol/L;But the CNR decreased from 50 to 100 mmol/L.The enhancement of superior colliculus were higher than optic nerve.Conclusion The optimal concentration of MnCl2 is 30 mmol/L(3 μL)through intravitreal injection for the rat visual pathway on 1.5T MEMRI.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Practical Radiology Year: 2015 Type: Article