Your browser doesn't support javascript.
loading
Preliminary study of peripheral artery CT angiography with auto-tube current of different tube voltage and noise index / 实用放射学杂志
Journal of Practical Radiology ; (12): 1531-1534, 2015.
Article in Zh | WPRIM | ID: wpr-479015
Responsible library: WPRO
ABSTRACT
Objective To evaluate the effect of different tube voltage and noise index (NI)on image quality and radiation dose during peripheral artery CTA with automatic tube current modulation(ATCM)technique.Methods Seventy-two patients were ran-domly divided into three groups with different scanning tube voltage and noise index as follows:group A with 100 kV and NI of 1 5, group B with 80 kV and NI of 1 5,group C with 100 kV and NI of 20.Image quality,segmental vascular enhancement,signal-to-noise ratio (SNR),contrast-to-noise (CNR)and effective dose (ED)were independently evaluated in 3 groups.The methods of sta-tistics analysis were ANOVA,and P 0.05).Conclusion Using ATCM low-kV with high NI scanning can reduce radiation dose without interference on image quality for peripheral artery CTA.
Key words
Full text: 1 Index: WPRIM Language: Zh Journal: Journal of Practical Radiology Year: 2015 Type: Article