Your browser doesn't support javascript.
loading
Techniques of Clinical Magnetic Resonance Imaging Scanner for the Imaging of Rat Pancreas / 中国医学影像学杂志
Chinese Journal of Medical Imaging ; (12): 654-658, 2015.
Article in Chinese | WPRIM | ID: wpr-479669
ABSTRACT
PurposeTo optimize the imaging parameters of clinical MRI scanner in rat pancreas imaging to improve the image quality and to provide better MRI image quality and more economical research method for imaging study of rat pancreas. Materials and Methods Twenty-four healthy male Wistar rats were randomly divided into the conventional sequence (CS) group, the adjustment sequence (AS) group and the optimization sequence (OS) group, with 8 rats in each group. The rats in the CS group were scanned with conventional parameters using a clinical MRI scanner. The principle of parameter adjustment was parameters associated with T1WI or T2WI imaging quality (TR, TE, slice thickness, NEX, FOV and matrix) was set with four changes, and only one of the six parameters was changed in each scan, image quality was evaluated by two senior radiologists, the parameter corresponded the best image quality evaluated consistently by two radiologists were selected as the optimal imaging parameter, all the optimized parameters were set up step by step in this way which formed the imaging parameters in OS group. The pancreatic signal intensity and signal to noise ratio was compared between CS group and OS group after imaging.Results The optimized sequence parameters in clinical MRI scanner were listed below T1WI sequence (M3D/FSPGR/15) TR 6 ms, TE 2.5 ms, slice thickness 2.0 mm, NEX 8, FOV 7 cm×7 cm, Matrix 120×120; T2WI sequence (FSE-XL/90) TR 4000 ms, TE 71 ms, slice thickness 2.0 mm, NEX 1, FOV 8 cm×8 cm, Matrix 192×160. The pancreatic SI in T1WI and T2WI sequence of the OS group were significantly higher than those in the CS group (t=5.16 and 3.80,P<0.01), while the pancreatic SNR in T1WI and T2WI sequence of the OS group were significantly higher than those in the CS group (t=5.65 and 3.26,P<0.01).Conclusion The optimized parameters can improve the imaging quality of rat pancreas MRI significantly, thus provide a reference for the related experimental study.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Medical Imaging Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Medical Imaging Year: 2015 Type: Article