Your browser doesn't support javascript.
loading
Reliability of ultrasound for rapid identification of esophageal intubation in patients with difficult airway / 中华麻醉学杂志
Chinese Journal of Anesthesiology ; (12): 848-850, 2015.
Article in Chinese | WPRIM | ID: wpr-479881
ABSTRACT
Objective To evaluate the reliability of ultrasound for rapid identification of esophageal intubation in the patients with difficult airway.Methods Twenty-one patients requiring orotracheal intubation, aged 20-75 yr, with body mass index of 25-32 kg/m2, of ASA physical status Ⅰ or Ⅱ , Cormack-Lehane grade Ⅲ or Ⅳ under direct laryngoscope, undergoing elective general anesthesia, were selected.The carotid artery, trachea and esophagus were identified by ultrasonic scanning at suprasternal notch before induction of anesthesia.After induction of anesthesia, tracheal intubation was performed.During intubation, ultrasound was performed to detect esophageal intubation.After intubation, mechanical ventilation was performed.Auscultation of bilateral breath sounds was carried out to evaluate the tube position.The position of the tube was subsequendy determined through partial pressure of end-tidal CO2 monitoring.Results The sensitivity and specificity of ultrasound in identifying esophageal intubation were both 100% in the patients with difficult airway.Conclusion Ultrasound can rapidly and effectively identify esophageal intubation in the patients with difficult airway.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study Language: Chinese Journal: Chinese Journal of Anesthesiology Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study Language: Chinese Journal: Chinese Journal of Anesthesiology Year: 2015 Type: Article