Analysis of patient radiation dose from nuclear medicine examinations / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection ; (12): 705-708, 2015.
Article in Chinese | WPRIM | ID: wpr-480991
ABSTRACT
Objective To measure and analyze the radiation dose for patients undergoing nuclear medicine examination,and to characterize radiation exposure of patients by using the estimated effective dose.Methods Patients undergoing nuclear medicine examinations were classified and the radiation doses from radiopharmaceuticals to patients were measured and calculated.Meanwhile,radiation exposure from computed tomography (CT) procedure was calculated on the basis of CT protocols and patients' information.The effective doses to patient from both the radiopharmaceutical and CT scan radiation were calculated and the factors influencing patient radiation doses were analyzed.Results For the patients undergoing positron emission tomography-computed tomography (PET-CT) examination,the average effective doses from positron radiopharmaceutical 18F-fluorodeoxyglucose (18F-FDG),18F-fluoro-l-thymidine (18 F-FLT),11C-choline,11 C-methylmethionine (11 C-MET) and 11 C-acetate (11 C-Ac) were (5.06 ± 0.73),(4.74±1.29),(1.71 ±0.05),(3.18±0.69) and (1.08±0.19) mSv,respectively.CTscan caused average effective dose was (8.80 ± 0.58) mSv.If a full diagnostic CT investigation was performed,the effective dose might be up to 27 mSv.Whereas for emission computed tomography (ECT) examinations,the average effective dose to the patients irradiated by single photon radiopharmaceutical 99Tcm-methylenediphosphonate (99Tcm-MDP),99Tcm-macroaggregated albumin (99Tcm-MAA),99Tcm-diethylentriaminpentaacetic acid (99 Tcm-DTPA),99Tcm-methoxyisobutyl isonitrile (99 Tcm-MIBI) and 99Tcm-pyrophosphate (99Tcm-PYP) were (4.63 ± 0.01),(1.71 ± 0.01),(1.18 ± 0.01),(7.19 ± 0.03) and (4.18 ± 0.01) mSv,respectively.Conclusions Radiopharmaceutical irradiation caused effective dose to the patients undergoing nuclear medicine examinations is from 1.08 to 7.19 mSv,while CT scan cause average effective dose is 8.80 mSv in PET-CT examination.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Practice guideline Language: Chinese Journal: Chinese Journal of Radiological Medicine and Protection Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Practice guideline Language: Chinese Journal: Chinese Journal of Radiological Medicine and Protection Year: 2015 Type: Article