Your browser doesn't support javascript.
loading
The interference evaluation of hyperlipidemia and hyperbilirubinaemia to HbA1c measurement with IE-HPLC method / 国际检验医学杂志
International Journal of Laboratory Medicine ; (12): 2492-2494, 2015.
Article in Chinese | WPRIM | ID: wpr-482495
ABSTRACT
Objective To investigate the interference of hyperlipidemia and hyperbilirubinaemia to HbA1c measurements by ion‐exchange high‐performance liquid chromatography(IE‐HPLC) method .Methods Fresh whole‐blood samples collected with EDTA‐K2 anticoagulant tubes were divided into four groupscontrol group(HbA1c<6 .2% ) ,diabetes group(HbA1c≥6 .2% ) ,hyperlipi‐demia group(TG 3 -20 mmol/L);hyperbilirubinaemis group (TBIL 21 -549 μmol/L) .HbA1c of these samples were measured with affinity chromatography(AC‐HPLC) and IE‐HPLC respectively .Results When HbA1c≤18 .7% ,r=0 .993 ;95% confidence interval(CI) of HbA1c results by using IE‐HPLC method was -0 .71 -0 .89 ;coefficient of variation was -5 .8% -6 .8% ;P=0 .198 and the difference was not statistically significant .When HbA1c< 16 .3% ,r= 0 .997;95% CI of HbA1c results with IE‐HPLC method is -0 .31-0 .67;coefficient of variation was -5 .8% -4 .3% .P=0 .000 and the difference was statistically signifi‐cant .No interference was detectded with the results ;When HbA1c was 16 .3% -18 .7% ,positive bias was observed with the re‐sults .When TG≤20 .78 mmol/L ,r=0 .995;95% CI of HbA1c results with IE‐HPLC method was -0 .26-0 .50 ;coefficient of var‐iation was -5 .5% -5 .8% .P=0 .000 and the difference was statistically significant .No interference was detectded with the re‐sults;When TBIL≤549 .3 μmol/L ,r=0 .990 ;95% CI of HbA1c results with IE‐HPLC method was -0 .08 -0 .63;coefficient of variation was -14% -4 .1% .P=0 .000 and the difference was statistically significant .When TBIL≤342 .1 μmol/L ,r= 0 .994 ;95% CI of HbA1c results with IE‐HPLC method was -0 .09-0 .50;coefficient of variation was -5 .5% -4 .1% .No interference was detectded with the results .When TBIL was 380 .7-549 .3 μmol/L ,negative bias was observed with the results .Conclusion Our data indicated that HbA1c measurement with IE‐HPLC method could resist the interference of hyperlipidemia;When TBIL≤380 .7 μmol/L and HbA1c<16 .3% ,the results could meet the needs of general clinical detection .Clinical staff should choose more specific HbA1c measurement method according to the patient's condition .

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: International Journal of Laboratory Medicine Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: International Journal of Laboratory Medicine Year: 2015 Type: Article