Your browser doesn't support javascript.
loading
Application observation of echocardiography in patients with transcatheter atrial septal defect closure / 中国医学装备
China Medical Equipment ; (12): 97-99, 2016.
Article in Chinese | WPRIM | ID: wpr-483787
ABSTRACT

Objective:

To study the application value of echocardiography in transcatheter atrial septal defect closure.

Methods:

Chosen 2012-2014 years our hospital 68 patients with transcatheter atrial septum closure, using the thoracic echocardiography in patients with transcatheter atrial septum closure under general anesthesia guided and cardiac function monitoring.

Results:

All 68 patients with atrial septal defects under the guidance and monitoring via thoracic echocardiography defect plugging successfully completed, the average operation time was (23.8±4.7)min; the average hospitalization day was (5.2±1.3)day. Three days, 3 months after operation, right ventricular end-diastolic diameters were narrowing (t=11.232,t=16.589;P<0.05); The right atrium insides were narrowing (t=10.573,t=14.793;P<0.05); left ventricular end-diastolic diameters, were increasing (t=9.378,t=12.245;P<0.05); pulmonary artery diameters were narrowing (t=10.026,t=13.873;P<0.05).

Conclusion:

Echocardiography can do the entire guide, cardiac function monitoring in transcatheter atrial septal defect closure, postoperative follow-up and curative effect evaluation.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Medical Equipment Year: 2016 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Medical Equipment Year: 2016 Type: Article