Your browser doesn't support javascript.
loading
Effects of different materials on stress distribution and biomechanics of bone interface of artificial hip joint / 中国组织工程研究
Chinese Journal of Tissue Engineering Research ; (53): 1268-1274, 2016.
Article in Chinese | WPRIM | ID: wpr-484814
ABSTRACT

BACKGROUND:

During joint replacement, different materials of prosthesis can be used. Different prosthesis can produce different effects and the stress distribution of bone interface.

OBJECTIVE:

To explore the effects of different materials on the stress distribution and biomechanics of the bone interface of artificial hip joint.

METHODS:

The CT scan of the hip was carried out. The image data were saved in DICOM format and processed by MIMICS software. The 3D finite element model of the femur was obtained by ANSYS. A three dimensional finite element model of the femur was made with the material properties of the femur. Three kinds of different replacement prosthesis materials (Co Cr Mo aloy, titanium aloy and composite materials) were selected, and the specific requirements of the actual joint replacement were selected, and different types of prosthesis were designed in CAE software. In the STL format, the prosthesis model was imported into MIMICS, and the femur and prosthesis were assembled. The stress status of different prosthesis was analyzed, and the stress shielding rates of exterior and interior sides of middle and lower parts of the femur, right to and 30 mm below lesser trochanter and right to lesser trochanter of the proximal femur were calculated. RESULTS AND

CONCLUSION:

Through three-dimensional finite element analysis, a direct and accurate model of the femur and the three-dimensional model of the prosthesis were established. According to the actual situation, material assignment of the femoral three-dimensional finite element model was conducted to obtain the corresponding model. Thus, the properties of different materials of the femur were shown visualy. The femoral stress of cobalt chromium molybdenum aloy, titanium aloy, and composite material was simulated after replacement. Results found that the stress shielding rate can decrease in the middle and lower parts of the femur. After replacement, the femoral stress is higher than that of the intact femur. The experimental results show that the stress shielding of the joint was performed after joint replacement with Co Cr Mo aloy, titanium aloy and composite materials. Among them, the composite material is more close to the actual physiological environment of the human body, and it can better reduce the stress shielding effect, and is beneficial to the stress from the prosthesis to the femur.
Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2016 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2016 Type: Article