Your browser doesn't support javascript.
loading
Closure of large full thickness stomach wall defect with a newly designed hemostatic clip / 中华消化内镜杂志
Chinese Journal of Digestive Endoscopy ; (12): 754-757, 2015.
Article in Chinese | WPRIM | ID: wpr-485240
ABSTRACT
Objective To design a hemostatic clip and evaluate its efficacy and success rate of closure of stomach wall defect after full thickness resection (FTR).Methods A full thickness circular or linear resection (3 to 5 cm) was made on each model's antrum with needle knife and insulated-tip knife.The specimens were divided into 2 groups, using either an interrupted or continuous suturing method.Then the closure condition, suturing time, number of clips required and success rate of closure were compared.Results All 12 defects were successfully closed.The average closing time of interrupted and continuous suturing group were 13.33 ± 1.09 and 10.17 ±2.11 minutes, and the mean number of clips used were 4.67 ± 0.82 and 2.67 ± 0.82.The success rate was 100%.Conclusion This newly designed clip is a fast, reliable and convenient tool for stomach wall defect closure after FTR.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Digestive Endoscopy Year: 2015 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Digestive Endoscopy Year: 2015 Type: Article