Your browser doesn't support javascript.
loading
Finite element analysis of fixed platform prosthesis and rotating platform prosthesis in total knee replacement / 中国组织工程研究
Chinese Journal of Tissue Engineering Research ; (53): 5801-5806, 2016.
Article in Chinese | WPRIM | ID: wpr-503491
ABSTRACT

BACKGROUND:

There are studies on three-dimensional finite element analysis of total knee replacement, but few research concerns contact pressure and contact area inside and outside polyethylene liner of fixed prosthesis and rotating platform prosthesis in total knee replacement.

OBJECTIVE:

To explore the contact pressure and contact area inside and outside polyethylene liner of fixed platform prosthesis and rotating platform prosthesis in total knee replacement.

METHODS:

We established three-dimensional finite element models of fixed platform prosthesis and rotating platform prosthesis in total knee replacement and compared contact pressure and contact area inside and outside polyethylene liner of fixed platform prosthesis and rotating platform prosthesis in total knee replacement. RESULTS AND

CONCLUSION:

The peak contact pressure inside and outside polyethylene liner of fixed platform prosthesis and rotating platform prosthesis in total knee replacement was minimum at 0° of genuflex. The peak contact pressure inside polyethylene liner was higher than that outside polyethylene liner of fixed platform prosthesis and rotating platform prosthesis in total knee replacement at 0°-90° of genuflex (P<0.05). The peak contact pressure inside and outside polyethylene liner of fixed platform prosthesis was higher than that of rotating platform prosthesis in total knee replacement at 60°-120° of genuflex (P<0.05). The contact area inside and outside polyethylene liner of fixed platform prosthesis and rotating platform prosthesis in total knee replacement was maximum at 0° of genuflex. The contact area inside polyethylene liner of fixed platform prosthesis in total knee replacement was lower than that of outside at 0°-30° of genuflex (P<0.05). The contact area inside polyethylene liner of fixed platform prosthesis in total knee replacement was lower than that of outside at 0°-90° of genuflex (P<0.05). The contact area inside and outside polyethylene liner of fixed platform prosthesis was lower than that of rotating platform prosthesis in total knee replacement at 30°-120° of genuflex (P<0.05). These results suggested that peak contact pressure inside polyethylene liner of fixed and rotating platform prostheses was higher than that outside in total knee replacement, and the inside contact area was lower than that of outside. Inside and outside contact pressure of the rotating platform prosthesis was lower than that of fixed platform prosthesis. Inside and outside contact area of the rotating platform prosthesis was higher than that of fixed platform prosthesis.
Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2016 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Tissue Engineering Research Year: 2016 Type: Article