Your browser doesn't support javascript.
loading
Influence of Duration of Scan Acquisition on Perfusion Parameters of Whole Renal Perfusion by Wide Detector Multidetector CT / 中国医学影像学杂志
Chinese Journal of Medical Imaging ; (12): 141-145, 2017.
Article in Chinese | WPRIM | ID: wpr-505823
ABSTRACT
Purpose To explore the influence of duration of scan acquisition on perfusion parameters in whole renal perfusion with Revolution CT.Materials and Methods Fortytwo patients without pathologic changes in bilateral kidneys were divided into group A (with short perfusion time) and group B (with long perfusion time) according to the duration time of the perfusion scan.The Revolution CT axial scan mode was used for perfusion scan,and the width of detector was 16 cm.The perfusion CT series were performed in 50 seconds,each comprising 25 volumes with identical parameters (80 kVp,200 mA) in group A.The perfusion CT series were performed in 594 seconds,each comprising 23 volumes with identical parameters (120 kVp,55 mA) in group B.The source datasets were post-processed with CT Perfusion 4D software,and the perfusion parameter maps were obtained when right renal abdominal aorta was taken as entry artery.Perfusion parameters of bilateral kidneys were compared within and between group A and group B,respectively.CT dosage index of volume (CTDIvol) and dose length product (DLP) were recorded.The effective dose (ED) was calculated and compared.Results There were no statistical difference in all parameters between bilateral kidneys within each group (P>0.05).However,blood volume,time to peak,and permeability surface in the cortex and medulla of bilateral kidneys all showed differences between the above two groups (P<0.05).The mean transit time in the medulla between the two groups was different (P<0.05),but neither the blood flow in the medulla and cortex nor the mean transit time of the cortex had difference between the two groups (P>0.05).The effective radiation doses were (23.10± 4.39)mSv in group A and (23.19±0.00) mSv in group B,respectively (without statistic differenceP>0.05).Conclusion CT perfusion parameters with different duration time show differences in whole renal perfusion;therefore,scanning time needs to be set according to the clinical application.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Medical Imaging Year: 2017 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Medical Imaging Year: 2017 Type: Article