Your browser doesn't support javascript.
loading
Content Determination of Urea in Urea [13C] Capsules by High Performance Cation-exchange Chromatogra-phy / 中国药房
China Pharmacy ; (12): 1236-1238, 2017.
Article in Chinese | WPRIM | ID: wpr-515069
ABSTRACT

OBJECTIVE:

To determine the content of urea in Urea [13C] capsules by high performance cation-exchange chroma-tography (HPCEC).

METHODS:

The determination was performed on Zorbax 300 SCX column with mobile phases consisting of acetonitrile-0.1% phosphoric acid (2080,V/V) at the flow rate of 1.0 mL/min. The detection wavelength was set at 200 nm and column temperature was 35 ℃. The sample size was 20 μL.

RESULTS:

The linear range of urea was 0.0039-1.0030 mg/ml(r=0.9997). The limit of quantitation was 3.918 μg/mL and the limit of detection was 0.975 μg/mL. RSDs of precision,stability and repetitive test were all lower than 2.0%. The recovery ranged 99.3%-101.0%(RSD=0.67%,n=9).

CONCLUSIONS:

The meth-od is simple,rapid,sensitive and suitable for the content determination of urea in Urea [13C] capsules.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2017 Type: Article