Your browser doesn't support javascript.
loading
The value of quantitative analysis with spectral CT imaging in the diagnosis of non-small cell lung cancer with different pathological types / 中华放射学杂志
Chinese Journal of Radiology ; (12): 257-261, 2017.
Article in Chinese | WPRIM | ID: wpr-515272
ABSTRACT
Objective To explore the value of quantitative parameters of spectral CT imaging in the diagnosis of non-small cell lung cancer (NSCLC) with different pathological types. Methods One hundred and thirty-six patients with NSCLC proved by pathology underwent chest plain and enhanced CT scan with gemstone spectral imaging (GSI) mode by Discovery CT750 HD, including 57 cases of squamous cell carcinoma (SQCC) and 79 cases of adenocarcinoma (ADC). All the cases were divided into two groups of tumor diameter>2 cm (120 cases, including 50 cases of SQCC and 70 cases of ADC) and diameter≤2 cm (16 cases, including 7 cases of SQCC and 9 cases of ADC). The slope between 40 and 65 keV(K40-65 keV) of spectral attenuation curve, effective atomic number (Eff-Z) and calcium concentration in plain scan (PS) and K40-65 keV of spectral attenuation curve, iodine concentration and water concentration in arterial phase (AP) of SQCC and ADC in the two groups were measured and compared respectively. Furthermore, all cases were classified according to the trend of spectral attenuation curve in PS. These quantitative parameters satisfying normal distribution were compared by two independent samples t test, while those parameters not satisfying normal distribution were compared by rank sum test. ROC curves was drawn for these parameters with statistical difference and area under the curve (AUC) was used to measure the differential diagnostic performance of each parameter. Chi square test was used to compare the differences of the trend of spectral attenuation curve in PS between SQCC and ADC. Results In the group of diameter>2 cm (1) Comparison of quantitative parameters of spectral CT in PSK40-65 keV, Eff-Z and calcium concentration of ADC were 0.69 ± 0.56, 7.76±0.19, and (4.11±2.93) mg/cm3, respectively. The corresponding parameters of SQCC were 0.19± 0.23, 7.59 ± 0.14, and (1.25 ± 1.59) mg/cm3, respectively. These parameters of ADC were significantly higher than SQCC (Z=-7.000,-6.249, t=-6.884, P0.05). The trend of spectrum attenuation curve in PS of all cases showed type Ⅱ. Conclusions Lung ADC and SQCC have different quantitative parameters in spectral CT imaging. These quantitative parameters are valuable in classifying the pathological type of NSCLC with diameter more than 2 cm.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study / Prognostic study Language: Chinese Journal: Chinese Journal of Radiology Year: 2017 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study / Prognostic study Language: Chinese Journal: Chinese Journal of Radiology Year: 2017 Type: Article