1H-MRS measurement of the hippocampus in chronic obstructive pulmonary disease / 实用放射学杂志
Journal of Practical Radiology
;
(12): 500-502, 2017.
Article
in Chinese
| WPRIM
| ID: wpr-515350
ABSTRACT
Objective To identify the features of 1H-magnetic resonance spectroscopy(1H-MRS) in patients with chronic obstructive pulmonary disease(COPD) of the hippocampus.Methods 32 patients with COPD randomly selected and 30 normal controls were selected.1H-MRS of the hippocampus was performed given to on all the subjects on hippocampus.The ratios of NAA/Cr and Cho/Cr were determined.Results In the bilateral hippocampus, the NAA/Cr ratio in patients with COPD demonstrated lower than that in normal controls(t=4.963,P=0.007 and t=4.856,P=0.023).The Cho/Cr ratio in patients with COPD showed higher than that in normal controls, the differences was were statistically significant(t=3.469,P=0.013 and t=3.019,P=0.047) Conclusion Abnormal metabolism of neurons on the hippocampus in patients with COPD is showed.
Full text:
Available
Index:
WPRIM (Western Pacific)
Language:
Chinese
Journal:
Journal of Practical Radiology
Year:
2017
Type:
Article
Similar
MEDLINE
...
LILACS
LIS