Your browser doesn't support javascript.
loading
Hemodynamic changese during the procedure or double cardiac valve replacement / 中华麻醉学杂志
Chinese Journal of Anesthesiology ; (12)1994.
Article in Chinese | WPRIM | ID: wpr-516302
ABSTRACT
The hemodynamics of 49 scheduled patients during anesthesia and opration for mitral and aortic valve replacement were studied with the insertion of SwanGanz catheter and by the method of thermodilution technics.Pre-anesthesia CI and LVWI were in the nor mal range with abnormal MPAP, PCWP, PTRI and RVWI.Increase of RAP and decrease in MPA,PCWP, MAP, CI, LVWI and RVWI were observed during induction of anesthesia. The hemodynamic parameters returned to or exceded the pre-anesthesia values after trachcal intubation and sternotomy. The CI, MAP, MPAP, PCWP, LVWI and RVWI decreased signifi- cantly after insertion of aorta and vena cava catheter. The reduction of MPAP, P(IWP,PTRI and RVWI post-cardiopulmonary bypass (CPB) were significant and persistent with no change of PVRI.The lower MAP,SVRI and deterioration of cardiac performance post-CPB indicate that the administeration of positive inotropir agents and restoration of hematocrit are nec essary as early as possible.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Anesthesiology Year: 1994 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Anesthesiology Year: 1994 Type: Article