Your browser doesn't support javascript.
loading
Comparison of Arterial and End-Tidal CO2 Tension by Position and Time Changes during Hip Replacement Arthroplasty in Elderly Patients / 대한마취과학회지
Korean Journal of Anesthesiology ; : 560-567, 2001.
Article in Korean | WPRIM | ID: wpr-51639
ABSTRACT

BACKGROUND:

Hip replacement arthroplasty (HRA) is highly traumatic and performed in a lateral position for several hours and dead-space ventilation may increase. So, the difference between arterial and end-tidal PCO2 was investigated depending on the changes in the patient's posture during HRA in elderly patients.

METHODS:

Forty-three patients scheduled for a HRA were divided into two groups; Adult Group (n = 21, A-Group) and Elderly Group (n = 22, E-Group). Mean arterial pressure (MAP), heart rate (HR), PaO2, PaCO2, and end-tidal carbon dioxide tension (P(ET)CO2) were simultaneously measured at 10 min after anesthesia in a supine position (S[10]), at 30 min intervals from 30 min (L[30]) to 180 min (L[180]) in a lateral position and at 10 min in a supine position after the end of surgery (ES[10]) in both groups. The PaCO2-P(ET)CO2 gradient (P[a-ET]CO2) and dead space ventilation (Vd/ Vt) were calculated.

RESULTS:

At S(10), P(a-ET)CO2 in the A- and E-Groups was 7.0 +/- 5.0 and 7.2 +/- 3.3 mmHg respectively. From L(30) to ES(10), the P(a-ET)CO2 and the ratio of Vd/Vt in both groups increased significantly and progressively (P < 0.05 vs the control value) and the slope in the E-Group rose two times as compared to that in the A-Group. The correlation coefficient between P(a)CO2 and P(ET)CO2 was very significant from S(10) to L(90) and ES(10) in the A-Group, and from S(10) to L (60) in the E-Group (P < 0.01).

CONCLUSIONS:

For maintaining adequate ventilation of the elderly patient during HRA, PaCO2 should be measured intermittently along with the position changes after anesthesia in addition to the constant monitoring of PETCO2.
Subject(s)

Full text: Available Index: WPRIM (Western Pacific) Main subject: Posture / Ventilation / Carbon Dioxide / Supine Position / Arthroplasty, Replacement, Hip / Arterial Pressure / Heart Rate / Hip / Anesthesia Limits: Adult / Aged / Humans Language: Korean Journal: Korean Journal of Anesthesiology Year: 2001 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Main subject: Posture / Ventilation / Carbon Dioxide / Supine Position / Arthroplasty, Replacement, Hip / Arterial Pressure / Heart Rate / Hip / Anesthesia Limits: Adult / Aged / Humans Language: Korean Journal: Korean Journal of Anesthesiology Year: 2001 Type: Article