Simultaneous Determination of the Contents of Fleroxacin and Tinidazole in Compound Fleroxacin Suppository by RP-HPLC / 中国药房
China Pharmacy ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-518183
ABSTRACT

OBJECTIVE:

To determine the contents of fleroxacin and tinidazole in compound fleroxacin suppository METH_ODSRP-HPLC was used,the detecting conditionsODS-C18 column;mobile phase,0 05mol/L lemon acid-acetonitrile(65∶35),was modulated to pH=4 0 with triethylamine;flow rate 0 8ml/min;external standard method;detective wavelength 300nm

RESULTS:

Linear ranges were 9 92~79 36?g/ml(for fleroxacin) 20 32~162 56?g/ml(for tinidazole) respectively wh_ere the peak areas were correlative with the concentrations,r=0 9 974 and 0 9 995 The average recoveries were 101 6% and 100 1% and RSDs was 1 4% and 1 2% respectively

CONCLUSION:

This detecting method is simple,rapid,accurate and suitable for determination of the contents of this preparation

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2001 Type: Article