Your browser doesn't support javascript.
loading
Determination of Concentration of Cefixime in Human Serum by RP-HPLC / 中国药房
China Pharmacy ; (12)1991.
Article in Zh | WPRIM | ID: wpr-520474
Responsible library: WPRO
ABSTRACT
OBJECTIVE:To establish a RP-HPLC method to determine concentration of cefixime in human serum.ME_ THODS:The assay was conducted on Agilent ZORBAX?SB C 18 column with methanal-water-PBS(25∶15∶60,V/V/V)as mobile phase.The detection wavelength was270nm,and the acetanilide was taken as internal standard.RESULTS:The lin?earity range was0.11~5.28mg/L with a regressive equation of Y-0.07534X-0.13186,r=0.9995.The recovery was high.CONCLUSION:This method is accurate,rapid and simple and can be used for determining the concentration of cefixime in human serum.
Key words
Full text: 1 Index: WPRIM Language: Zh Journal: China Pharmacy Year: 1991 Type: Article