OBJECTIVE:

To establish a RP-HPLC method to determine concentration of cefixime in human serum.ME_ THODSThe assay was conducted on Agilent ZORBAX?SB C 18 column with methanal-water-PBS(25∶15∶60,V/V/V)as mobile phase.The detection wavelength was270nm,and the acetanilide was taken as internal standard.

RESULTS:

The lin?earity range was0.11~5.28mg/L with a regressive equation of Y-0.07534X-0.13186,r=0.9995.The recovery was high.

CONCLUSION:

This method is accurate,rapid and simple and can be used for determining the concentration of cefixime in human serum.