Determination of Cilostazol Concentration in Human Plasma by HPLC / 中国药房
China Pharmacy ; (12)1991.
Article in Chinese | WPRIM | ID: wpr-524418
ABSTRACT

OBJECTIVE:

To propose a HPLC method for quantitative assessment of cilostazol in human plasma.

METHODS:

Chromatogram column was C18(150mm?4.6mm, 5?m), mobile phases were acetonitrile-water(40∶60,V/V), the flow rate was 1.4ml/min,determined wavelength was 254nm.

RESULTS:

Cilostazol concentration was in the linear range of 25~2000ng/ml(r=0.9 999)with the lowest determinable concentration of 12.5ng/ml,recoveries of cilostazol from plasma were 99.99%~101.44%,the relative standard variation of intra-day and inter-day were 0.20%~2.90% and 0.19%~2.13%(n=5) respectively.

CONCLUSIONS:

This method is s simple, convenient, accurate, and applicable for study of pharmacokinetics of cilostazol in clinic.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 1991 Type: Article