Content Determination of 2 Components in Tetracaine Hydrochloride Mucilage by RP-HPLC / 中国药房
China Pharmacy ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-524509
ABSTRACT

OBJECTIVE:

To establish a method for the content determination of tetracaine hydrochloride and ethyl hy-droxybenzoate in tetracaine hydrochloride mucilage by RP-HPLC.

METHODS:

C 8 was the chromatographic column,the mobile phase was methanol-absolute ethanol-water-triethylamine(70∶15∶15∶0.05),the detection wavelength was at280nm.

RESULTS:

The linear ranges of tetracaine hydrochloride and ethyl hydroxybenzoate were10~50?g/ml(r=0.9997)and2~10?g/ml(r=0.9999)respectively;the average recovery rate were100.82%and100.16%respectively.

CONCLUSIONS:

The method was simple,rapid and accurate,which can be used for the quality control of tetracaine hydrochloride mucilage.