Your browser doesn't support javascript.
loading
Simultaneous Determination of Blood Drug Concentration of Acetaminophen and Phenacetin by HPLC / 中国药房
China Pharmacy ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-524663
ABSTRACT

OBJECTIVE:

To establish a HPLC method for the simultaneous determination of blood drug concentration of acetaminophen and phenacetin.

METHODS:

Diamonil C 18 was used as the chromatographic column,the mobile phase was methanol-water(45∶55),theophyllinum was used as internal standard,the detection wavelength was254nm and the column temperature was set at the room temperature.

RESULTS:

The minimum determination concentration of acetaminophen and phenacetin was5?g/ml,the calibration curve was linear in a range from5~25?g/ml;The recovery rate of both acetaminophen and phenacetin in this method was more than95%;both the intraday RSD and the interday RSD were less than4.0%.

CONCLUSION:

The method is rapid and accurate,which can satisfy the needs of the clinic blood drug concentration deter-mination of paracetamol and phenacetin.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2001 Type: Article

Similar

MEDLINE

...
LILACS

LIS