OBJECTIVE:
To determine the contents of secnidazole in secnidazol e tablets by RP-HPLC.METHODS:
The chromatographic column was VP-ODS C 18 with acetonirile-0.05mol/L potassium dihydrogen phosphate-triethylamine(15∶85∶0.4)as the mobile phase,the detection wavelength was311nm and the flow rate was0.8ml/min.RESULTS:
There was a good linear relationship when the sample size was within the range of0.166?g~0.832?g(r=0.9999),the average re?covery was99.84%(RSD=1.05%,n=15).CONCLUSION:
The method is simple and accurate,sensible and reproducible,which can be used for the assaying of both the raw materials and preparations and the quality control of secnidazole tablets.