Your browser doesn't support javascript.
loading
Determination of Secnidazole in Secnidazole Tablets by RP-HPLC / 中国药房
China Pharmacy ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-524858
ABSTRACT

OBJECTIVE:

To determine the contents of secnidazole in secnidazol e tablets by RP-HPLC.

METHODS:

The chromatographic column was VP-ODS C 18 with acetonirile-0.05mol/L potassium dihydrogen phosphate-triethylamine(15∶85∶0.4)as the mobile phase,the detection wavelength was311nm and the flow rate was0.8ml/min.

RESULTS:

There was a good linear relationship when the sample size was within the range of0.166?g~0.832?g(r=0.9999),the average re?covery was99.84%(RSD=1.05%,n=15).

CONCLUSION:

The method is simple and accurate,sensible and reproducible,which can be used for the assaying of both the raw materials and preparations and the quality control of secnidazole tablets.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2001 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2001 Type: Article