ABSTRACT

OBJECTIVE:

To establish a HPLC method for the determination of levofloxacin hydrochloride in the levoflo_ xacin hydrochloride ointment.

METHODS:

The chromatographic column was C 18 ,the mobile phase was consisted of0.05mol/L citric acid-acetonitrile(85∶15)with detection wavelength at293nm and flow speed at1.0ml/min,the column temperature was40℃and the sample size was10?l.

RESULTS:

Good linear relation was achieved when the levofloxacin hydrochloride concen-tration was at the range of3.88~37.88ug/ml(r=0.9998);The average recovery was99.4%(n=9).

CONCLUSION:

This determination method is accurate,reliable and it can act as an effective quality control for levofloxacin hydrochloride ointment.